Welcome to Hebei Bendin Industrial Technology Co., Ltd.
19567910927

50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough

Basic Properties
Brand Name: BDINDUSTRIAL
Certification: ISO, CE
Model Number: cable tray-006
Trading Properties
Minimum Order Quantity: 100mm
Price: 10-50usd per meter
Payment Terms: L/C,T/T,Western Union
Supply Ability: 10000m per week
Product Summary
50mm galvanised cable tray Bending company's 50mm galvanised cable tray specification& positioning The core parameters and application positioning of the "50mm Galvanized Cable Tray" are summarized in the table below: Parameter Dimension Typical Specification Description Application Characteristic ...

Product Details

Highlight:

fire resistance hot dip cable tray

,

50mm galvanised cable tray fire resistance

,

hot dip cable tray trough

Product Name: 50mm Cable Tray
Color: Customize
Material: Galvanized/hot Dipped Galvanized/electric Galanized
Length: 3m Or Customize
Type: Slot /wire Mesh/ladder
Key Words: Galvanized Cable Tray
Product Description

50mm galvanised cable tray

 

Bending company's 50mm galvanised cable tray specification& positioning

The core parameters and application positioning of the "50mm Galvanized Cable Tray" are summarized in the table below:

 
 
Parameter Dimension Typical Specification Description Application Characteristic Interpretation
Channel Height 50mm (Internal clear height) Determines its suitability for cables with smaller outer diameters (e.g., control cables, instrument signal cables, small-to-medium specification power cables).
Material Thickness National standard requirements: side/base plate typically ≥1.0mm (specifics depend on load class). Provides basic structural support, falling into the light to medium-duty load category, distinct from "heavy-duty trays."
Width Series Common: 100mm, 150mm, 200mm, 300mm, 400mm, 500mm, etc. When selecting width, ensure the total cross-sectional area of cables does not exceed 40%-50% of the tray's internal cross-sectional area.
Surface Treatment Hot-dip galvanizing or electro-galvanizing. Hot-dip galvanizing (zinc coating ≥55μm) offers better corrosion resistance and is preferred for outdoor and industrial environme
nts.
The zinc coating provides basic rust protection, suitable for general indoor and dry outdoor environments. For high-corrosion areas like chemical plants or coastal regions, assessment is needed, or stainless steel should be considered.
Load & Span Safe working load is typically < 100 kg/m, with support spans generally between 1.5 to 3 meters. Spans must be strictly calculated based on actual cable weight to prevent excessive sagging.

 

50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough 0

Bending company's 50mm galvanised cable tray Primary Application Scenarios

Due to its moderate capacity and cost, the 50mm high galvanized tray is widely used in:

  • Building Electrical Systems: Horizontal and vertical routing for lighting, socket outlets, and low-voltage (network, telephone) lines in office buildings, shopping malls, and residential complexes.

  • Industrial Control: Tray systems for control cables, instrument signal cables, and low-voltage power lines in factory production lines and equipment rooms.

  • Small Equipment Rooms: Cable convergence and management above or below network cabinets.

  • Lightweight Equipment Floors: Cable routing in equipment mezzanines with low space and load requirements.

Bending company's 50mm galvanised cable tray Important Selection & Installation Notes

To ensure safety and reliability, pay attention to the following during selection and installation:

  1. Accurate Load Calculation: Always calculate the total weight of all cables and determine appropriate support spacing based on the supplier's load-span curve. Avoid tray deformation due to overload.

  2. Distinguish "Heavy-Duty" vs. "General Purpose": A 50mm high tray typically does not fall into the "heavy-duty" category. For heavier cables or longer span requirements, choose a model with higher side walls, thicker plates, and stiffeners, and request load test reports.

  3. Environmental Suitability: In damp or chemically aggressive environments, verify if the hot-dip galvanizing thickness is sufficient, or consider trays with galvanizing plus powder coating ("zinc + plastic") for better protection.

  4. System Integrity: Ensure the use of original or compatible connection plates, screws, and bonding jumpers to guarantee electrical continuity and structural strength.

    50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough 1

Bending company's 50mm galvanised cable tray Summary:

The "50mm Galvanized Cable Tray" is a cost-effective, general-purpose cable routing solution. The key to its successful application is: precisely matching the cable scale, strictly controlling support spans, and ensuring it is used within its designed environmental conditions. For more demanding loads or environments, higher-grade products should be considered.

50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough 2

50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough 3

50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough 4

50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough 5

50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough 6

50mm Galvanised Cable Tray Fire Resistance Hot Dip Cable Tray Trough 7

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Related Products
  • swift cable ladder

    The Bending swift cable ladder Tray is a type of cable management system widely used in industrial, commercial, and infrastructure projects to support and organize electrical cables, wiring, and sometimes pneumatic or hydraulic lines.
  • electrical ladder tray

    The Bending Electrical Ladder Tray is a type of cable management system widely used in industrial, commercial, and infrastructure projects to support and organize electrical cables, wiring, and sometimes pneumatic or hydraulic lines.
  • Fiberglass cable ladder

    The Bending Fiberglass Cable Ladder is a lightweight, high-strength, and corrosion-resistant cable management system, widely used in industrial, commercial, and infrastructure projects for organizing and supporting power, control, and communication cables.
  • 450mm Cable Ladder

    The Bending Light Duty Cable Ladder is a lightweight and cost-effective cable support system designed for routing control, signal, communication, and low-voltage power cables in indoor and light industrial environments. It provides reliable cable management while avoiding over-engineering and unnecessary cost. Bending Light Duty Cable Ladder Key Features Light Load Design: Engineered for low to moderate cable weights Lightweight Structure: Easy handling, faster installation,

Send An Inquiry